•Considering a perfect gas model, the following formula can be established:
•Experiments with a blind basket and the DE1PRO machine show acceptable validity of this formula 3
•P: absolute pressure (in bar) –P0: 1 bar = atmospheric pressure
•t: time (in seconds) –t0: the system becomes air tight due to the
presence of a continuous water bed above the puck
•HS 1: initial headspace (in cm3)
IT’S ALMOST A BLIND BASKET
SUMMARY (2/3)
3
•Vinput
2: total volume of water dispensed by the pumps
after t0(in cm3/s)
•Vexit: total volume of water that has flown through the
top surface of the puck
1 mL/s
2 mL/s
4 mL/s
1Headspace is often described as the distance from the
top of the puck to the shower screen –in this document it
represents the total air volume trapped above the coffee
puck, including between the screen and the brass diffuser
2For liquid water we assume 1 cm3= 1 mL
With a constant water flow, Vinput = Flow rate * (t - t0)
3For this experiment, the trigger to switch from the initial
flow rate to 0 mL/s was set to 7 bar
Input water flow rate: